Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | FilterType | Configuration | Voltage-RatedDC | Voltage-RatedAC | Voltage-RatedAC(PhasetoGround/Neutral) | Voltage-RatedAC(PhasetoPhase) | Current | Frequency-Operating | Applications | ApprovalAgency | OperatingTemperature | MountingType | TerminationStyle |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
FN258HVIT-130-35LINE FILTER 130A CHASSIS MOUNT |
3,411 | 852.08 |
RFQ |
![]() Datasheet |
Tray | FN 258 | Not For New Designs | Three Phase (Delta) | Two Stage | - | - | 400 V | 690 V | 130 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block |
![]() |
FN3310-600-99-R5LINE FILTER 520VAC 600A CHASS |
3,194 | 859.49 |
RFQ |
![]() Datasheet |
Box | FN 3310 | Active | Three Phase (Delta) | Single Stage | - | 520V | - | 520 V | 600 A | DC ~ 60Hz | General Purpose | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post |
![]() |
FMBD-B92F-J612LINE FILTER 300/520VAC 160A CHAS |
3,740 | 934.67 |
RFQ |
![]() Datasheet |
Bulk | FMBD NEO | Active | Three Phase (Wye) | Two Stage | - | 300V, 520V | - | - | 160 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block |
![]() |
FN3310-1000-99-R5LINE FILTER 520VAC 1KA CHASS MNT |
3,115 | 1047.50 |
RFQ |
![]() Datasheet |
Box | FN 3310 | Active | Three Phase (Delta) | Single Stage | - | 520V | - | 520 V | 1 kA | DC ~ 60Hz | General Purpose | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post |
![]() |
FN5040-24-84LINE FILTER 24A CHASSIS MOUNT |
2,358 | 1097.25 |
RFQ |
![]() Datasheet |
Box | FN 5040 | Not For New Designs | Three Phase (Delta) | Single Stage | - | - | - | - | 24 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block |
![]() |
FN3310-1500-99-R5LINE FILTER 520VAC 1.5KA CHASS |
2,442 | 1396.67 |
RFQ |
![]() Datasheet |
Box | FN 3310 | Active | Three Phase (Delta) | Single Stage | - | 520V | - | 520 V | 1.5 kA | DC ~ 60Hz | General Purpose | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post |
![]() |
FN3311-1500-99-C16-R55LINE FLTR 520/300VAC 1.5KA CHASS |
3,139 | 1553.32 |
RFQ |
![]() Datasheet |
Box | FN 3311 | Active | Three Phase (Delta) | Single Stage | - | 520V, 300V | 300 V | 520 V | 1.5 kA | 60Hz | General Purpose | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post |
![]() |
FN3310-2300-99-R5LINE FILTER 520VAC 2.3KA CHASS |
2,366 | 1718.98 |
RFQ |
![]() Datasheet |
Box | FN 3310 | Active | Three Phase (Delta) | Single Stage | - | 520V | - | 520 V | 2.3 kA | DC ~ 60Hz | General Purpose | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post |
![]() |
FN2210-2300-99-R5LINE FILTER 1KVDC 2.3KA CHASS |
3,019 | 1765.28 |
RFQ |
![]() Datasheet |
Box | FN 2210 | Active | DC | Single Stage | 1000V (1kV) | - | - | - | 2.3 kA | DC | Inverters, Power Drive Systems | CE, cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post |
![]() |
BL2010-1-FSINGLE PHASE EMC/EMI LINE FILTER |
128 | 3.61 |
RFQ |
![]() Datasheet |
Box | BL2010 | Active | Single Phase | Single Stage | - | 250V | - | - | 1 A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect |
![]() |
080M.00301.00HIGH PERF IEC INLET FILTER |
3,813 | 4.96 |
RFQ |
![]() Datasheet |
Box | 080 | Active | Single Phase | Single Stage | - | 250V | - | - | 3 A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 85°C | Chassis Mount | IEC Inlet-C14, Quick Connect |
![]() |
BL2090B-1-FSINGLE PHASE EMC/EMI LINE FILTER |
2,467 | 4.99 |
RFQ |
![]() Datasheet |
Box | BL2090 | Active | Single Phase | Two Stage | - | 250V | - | - | 1 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect |
![]() |
080.00301.00HIGH PERF IEC INLET FILTER |
2,373 | 5.08 |
RFQ |
![]() Datasheet |
Box | 80 | Active | Single Phase | Single Stage | - | 250V | - | - | 3 A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 85°C | Chassis Mount | IEC Inlet-C14, Quick Connect |
![]() |
BL2030-12-FSINGLE PHASE EMC/EMI LINE FILTER |
2,388 | 5.88 |
RFQ |
![]() Datasheet |
Box | BL2030 | Active | Single Phase | Single Stage | - | 250V | - | - | 12 A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect |
![]() |
RP180-15-2.2-QDSNGL STAGE IEC INLET FILTER |
3,101 | 6.65 |
RFQ |
![]() Datasheet |
Box | RP180 | Active | Single Phase | Single Stage | - | 250V | - | - | 15 A | 50/60Hz | General Purpose | CE, cURus, ENEC | -25°C ~ 100°C | Chassis Mount | IEC 320-C14, Quick Connect |
![]() |
BL2090-12-FSINGLE PHASE EMC/EMI LINE FILTER |
100 | 10.10 |
RFQ |
![]() Datasheet |
Box | BL2090 | Active | Single Phase | Two Stage | - | 250V | - | - | 12 A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect |
![]() |
091.01001.00HIGH PERF SINGLE PH SNGL STAGE E |
3,130 | 10.85 |
RFQ |
![]() Datasheet |
Box | 91 | Active | Single Phase | Single Stage | - | 250V | - | 1.45 kV | 10 A | 50/60Hz | General Purpose | CE, cURus, SEMKO | -25°C ~ 85°C | Chassis Mount | IEC 320-C14, Quick Connect |
![]() |
BL2080B-6-FSINGLE PHASE EMC/EMI LINE FILTER |
100 | 10.90 |
RFQ |
![]() Datasheet |
Box | BL2080 | Active | Single Phase | Two Stage | - | 250V | - | - | 6 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect |
![]() |
BL2080-6-FSINGLE PHASE EMC/EMI LINE FILTER |
100 | 10.90 |
RFQ |
![]() Datasheet |
Box | BL2080 | Active | Single Phase | Two Stage | - | 250V | - | - | 6 A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect |
![]() |
AMI-21-10-1LINE FILTER 250VAC 10A CHASS MNT |
2,537 | 11.15 |
RFQ |
![]() Datasheet |
Box | AMI-21 | Active | Single Phase | Single Stage | - | 250V | - | - | 10 A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect |